Ketersediaan: | |
---|---|
Kuantitas: | |
J52XFW975B
Berangin
Parameter utama (Bagian 1)
Model | J52XFW975BL | J52XFDW9752 | J52XFDW9753 | J52XFDW9754 | J52XFDW9755 |
Pasangan tiang | 1 | 2 | 3 | 4 | 5 |
Tegangan input | AC 7 VRMS | AC 7 VRMS | AC 7 VRMS | AC 7 VRMS | AC 7 VRMS |
Frekuensi input | 10000 Hz | 10000 Hz | 10000 Hz | 10000 Hz | 10000 Hz |
Rasio transformasi | 0,5 ± 10% | 0,5 ± 10% | 0,5 ± 10% | 0,5 ± 10% | 0,5 ± 10% |
Ketepatan | ± 10 'maks | ± 10 'maks | ± 10 'maks | ± 10 'maks | ± 10 'maks |
Pergeseran fase | 9 ° ± 3 ° | 9 ° ± 3 ° | 7 ° ± 3 ° | 4 ° ± 3 ° | 0 ° ± 10 ° |
Impedansi Input | (120 ± 18) Ω | (175 ± 27) Ω | (170 ± 26) Ω | (90 ± 14) Ω | (85 ± 13) Ω |
Impedansi output | (360 ± 54) Ω | (490 ± 74) Ω | (577 ± 87) Ω | (530 ± 80) Ω | (1650 ± 248) Ω |
Kekuatan dielektrik | AC 500 VRMS 1 menit | ||||
Resistensi isolasi | 250 mΩ mnt | ||||
Kecepatan rotasi maksimum | 20000 RPM | 15000 rpm | 12000 rpm | ||
Kisaran suhu operasi | -55 ℃ hingga +155 ℃ |
Parameter utama (Bagian 2)
Model | J52XFW575 |
Pasangan tiang | 1 |
Tegangan input | AC 7 VRMS |
Frekuensi input | 5000 Hz |
Rasio transformasi | 0,5 ± 10% |
Ketepatan | ± 12 '(pp) |
Pergeseran fase | 0 ° ± 3 ° |
Impedansi Input | (130 ± 26) Ω |
Impedansi output | (500 ± 100) Ω |
Kekuatan dielektrik | AC 500 VRMS 1 menit |
Resistensi isolasi | 250 mΩ mnt |
Kecepatan rotasi maksimum | 20000 RPM |
Kisaran suhu operasi | -55 ℃ hingga +155 ℃ |
Pasangan tiang di Resolvers
Seorang resolver, menjadi alat listrik yang menancam energi listrik dan mekanik, dilengkapi dengan kumparan dan inti magnetik. Jumlah pasangan tiang adalah parameter kritis yang mewakili rasio jumlah kutub dalam belitan primer dan sekunder transformator dalam resolver. Jumlah ini berbanding lurus dengan tegangan transformator dan kapasitas transfer daya. Jumlah pasangan tiang yang lebih tinggi memungkinkan penggunaan kumparan dan inti yang lebih kecil untuk mencapai transfer daya yang setara, meningkatkan efisiensi dan berpotensi mengurangi ukuran fisik perangkat.
Faktor yang mempengaruhi
Beberapa elemen dapat mempengaruhi jumlah pasangan tiang dalam resolver:
Ukuran dan bahan inti: Dimensi fisik dan bahan inti sangat penting. Bahan harus mampu menahan kekuatan medan magnet yang diperlukan dan panas sambil membanggakan intensitas induksi magnetik saturasi tinggi dan permeabilitas rendah untuk memastikan kinerja yang optimal.
Panjang kumparan dan luas penampang: Panjang dan luas penampang koil adalah faktor penentu. Gulungan yang lebih panjang, pada area cross-sectional tertentu, dapat memiliki lebih banyak belokan, yang mengarah ke jumlah pasangan tiang yang lebih tinggi. Selain itu, luas penampang coil harus memadai untuk menangani operasi kontinu dengan kehilangan resistansi minimal.
Aplikasi dan implikasi
Pilihan pasangan tiang tidak sewenang -wenang. Ini secara langsung mempengaruhi efisiensi dan kinerja transformator. Sejumlah pasangan tiang yang tidak tepat - baik terlalu tinggi atau terlalu rendah - dapat berdampak buruk pada transfer daya dan stabilitas tegangan. Oleh karena itu, selama fase desain, penting untuk menghitung dan menyempurnakan jumlah pasangan tiang berdasarkan persyaratan operasional tertentu. Pendekatan yang disesuaikan ini memastikan bahwa resolver beroperasi pada puncaknya, memberikan kinerja yang diinginkan dan kemampuan transfer daya.
Parameter utama (Bagian 1)
Model | J52XFW975BL | J52XFDW9752 | J52XFDW9753 | J52XFDW9754 | J52XFDW9755 |
Pasangan tiang | 1 | 2 | 3 | 4 | 5 |
Tegangan input | AC 7 VRMS | AC 7 VRMS | AC 7 VRMS | AC 7 VRMS | AC 7 VRMS |
Frekuensi input | 10000 Hz | 10000 Hz | 10000 Hz | 10000 Hz | 10000 Hz |
Rasio transformasi | 0,5 ± 10% | 0,5 ± 10% | 0,5 ± 10% | 0,5 ± 10% | 0,5 ± 10% |
Ketepatan | ± 10 'maks | ± 10 'maks | ± 10 'maks | ± 10 'maks | ± 10 'maks |
Pergeseran fase | 9 ° ± 3 ° | 9 ° ± 3 ° | 7 ° ± 3 ° | 4 ° ± 3 ° | 0 ° ± 10 ° |
Impedansi Input | (120 ± 18) Ω | (175 ± 27) Ω | (170 ± 26) Ω | (90 ± 14) Ω | (85 ± 13) Ω |
Impedansi output | (360 ± 54) Ω | (490 ± 74) Ω | (577 ± 87) Ω | (530 ± 80) Ω | (1650 ± 248) Ω |
Kekuatan dielektrik | AC 500 VRMS 1 menit | ||||
Resistensi isolasi | 250 mΩ mnt | ||||
Kecepatan rotasi maksimum | 20000 RPM | 15000 rpm | 12000 rpm | ||
Kisaran suhu operasi | -55 ℃ hingga +155 ℃ |
Parameter utama (Bagian 2)
Model | J52XFW575 |
Pasangan tiang | 1 |
Tegangan input | AC 7 VRMS |
Frekuensi input | 5000 Hz |
Rasio transformasi | 0,5 ± 10% |
Ketepatan | ± 12 '(pp) |
Pergeseran fase | 0 ° ± 3 ° |
Impedansi Input | (130 ± 26) Ω |
Impedansi output | (500 ± 100) Ω |
Kekuatan dielektrik | AC 500 VRMS 1 menit |
Resistensi isolasi | 250 mΩ mnt |
Kecepatan rotasi maksimum | 20000 RPM |
Kisaran suhu operasi | -55 ℃ hingga +155 ℃ |
Pasangan tiang di Resolvers
Seorang resolver, menjadi alat listrik yang menancam energi listrik dan mekanik, dilengkapi dengan kumparan dan inti magnetik. Jumlah pasangan tiang adalah parameter kritis yang mewakili rasio jumlah kutub dalam belitan primer dan sekunder transformator dalam resolver. Jumlah ini berbanding lurus dengan tegangan transformator dan kapasitas transfer daya. Jumlah pasangan tiang yang lebih tinggi memungkinkan penggunaan kumparan dan inti yang lebih kecil untuk mencapai transfer daya yang setara, meningkatkan efisiensi dan berpotensi mengurangi ukuran fisik perangkat.
Faktor yang mempengaruhi
Beberapa elemen dapat mempengaruhi jumlah pasangan tiang dalam resolver:
Ukuran dan bahan inti: Dimensi fisik dan bahan inti sangat penting. Bahan harus mampu menahan kekuatan medan magnet yang diperlukan dan panas sambil membanggakan intensitas induksi magnetik saturasi tinggi dan permeabilitas rendah untuk memastikan kinerja yang optimal.
Panjang kumparan dan luas penampang: Panjang dan luas penampang koil adalah faktor penentu. Gulungan yang lebih panjang, pada area cross-sectional tertentu, dapat memiliki lebih banyak belokan, yang mengarah ke jumlah pasangan tiang yang lebih tinggi. Selain itu, luas penampang coil harus memadai untuk menangani operasi kontinu dengan kehilangan resistansi minimal.
Aplikasi dan implikasi
Pilihan pasangan tiang tidak sewenang -wenang. Ini secara langsung mempengaruhi efisiensi dan kinerja transformator. Sejumlah pasangan tiang yang tidak tepat - baik terlalu tinggi atau terlalu rendah - dapat berdampak buruk pada transfer daya dan stabilitas tegangan. Oleh karena itu, selama fase desain, penting untuk menghitung dan menyempurnakan jumlah pasangan tiang berdasarkan persyaratan operasional tertentu. Pendekatan yang disesuaikan ini memastikan bahwa resolver beroperasi pada puncaknya, memberikan kinerja yang diinginkan dan kemampuan transfer daya.